Fotolab/Development Times: Unterschied zwischen den Versionen

aus Metalab Wiki, dem offenen Zentrum für meta-disziplinäre Magier und technisch-kreative Enthusiasten.
Zur Navigation springenZur Suche springen
 
(8 dazwischenliegende Versionen von 3 Benutzern werden nicht angezeigt)
Zeile 19: Zeile 19:
 
! Temperature
 
! Temperature
 
! comments / result
 
! comments / result
 +
|-
 +
| APX-100
 +
| 100
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 7'
 +
| 20ºC
 +
| ++
 
|-
 
|-
 
| APX-100  
 
| APX-100  
Zeile 28: Zeile 37:
 
| 21ºC
 
| 21ºC
 
| with lomo so exposure is kinda sorta 400, film turned out nice for most of the exposures
 
| with lomo so exposure is kinda sorta 400, film turned out nice for most of the exposures
 +
|-
 +
| APX-100
 +
| 400
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 12'
 +
| 20ºC
 +
| +, very contrasty
 +
|-
 +
| APX-100
 +
| 400
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 11'
 +
| 20ºC
 +
| ++
 
|-
 
|-
 
| Efke 50
 
| Efke 50
Zeile 37: Zeile 64:
 
| 22ºC
 
| 22ºC
 
| ++
 
| ++
 +
|-
 +
| TX-400
 +
| 400
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 5'
 +
| 24ºC
 +
| ++
 +
|-
 +
| TX-400
 +
| 400
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 8'
 +
| 20ºC
 +
| ++, slightly too contrasty negative?
 +
|-
 +
| Tmax-400
 +
| 400
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 5'40''
 +
| 20ºC
 +
| ++
 +
|-
 +
| Tmax-400
 +
| 400
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 6'
 +
| 20ºC
 +
| ++
 +
|-
 +
| HP4+-125
 +
| 125
 +
| HC-110
 +
| B
 +
| 30s then 10s per minute
 +
| 6'
 +
| 20ºC
 +
| ++
 +
|-
 +
| Kentmere 400
 +
| 400
 +
| Rodinal
 +
| 1+25
 +
| 30s then 10s per minute
 +
| 7' 10"
 +
| 20ºC
 +
| +, slightly too weak contrast
 +
|-
 
|}
 
|}
 +
 +
[[Kategorie:English]]
 +
[[Kategorie:Fotolab]]

Aktuelle Version vom 24. März 2013, 18:32 Uhr

Development Times Table

This is an attempt to collect development times that users of the fotolab have tried and tested. The 'ISO' column is for the EI at which the film was exposed at. For example if you take TX-400 and expose it at EI 3200 to push it put '3200' in that colum.

For the 'comments / result' column you might use the following abbreviations:

  • very good: ++
  • good: +
  • ok: 0
  • still useable: -
  • unuseable: --
Film ISO Developer Dilution Agitation Time Temperature comments / result
APX-100 100 HC-110 B 30s then 10s per minute 7' 20ºC ++
APX-100 400 HC-110 B 30s then 8s per minute 10' 21ºC with lomo so exposure is kinda sorta 400, film turned out nice for most of the exposures
APX-100 400 HC-110 B 30s then 10s per minute 12' 20ºC +, very contrasty
APX-100 400 HC-110 B 30s then 10s per minute 11' 20ºC ++
Efke 50 50 HC-110 B 30s then 10s per minute 6'30" 22ºC ++
TX-400 400 HC-110 B 30s then 10s per minute 5' 24ºC ++
TX-400 400 HC-110 B 30s then 10s per minute 8' 20ºC ++, slightly too contrasty negative?
Tmax-400 400 HC-110 B 30s then 10s per minute 5'40 20ºC ++
Tmax-400 400 HC-110 B 30s then 10s per minute 6' 20ºC ++
HP4+-125 125 HC-110 B 30s then 10s per minute 6' 20ºC ++
Kentmere 400 400 Rodinal 1+25 30s then 10s per minute 7' 10" 20ºC +, slightly too weak contrast