Mounting information:
Mounting information:


  * An Air gap of 8mm or more will be required between the LCD panel and the touch sensor.
* An Air gap of 8mm or more will be required between the LCD panel and the touch sensor.
  * In all cases the earth cable provided with the touchfoil™ controller MUST be connected to the metal CASE/CHASSIS of the LCD. The whole setup should be very well grounded.
* In all cases the earth cable provided with the touchfoil™ controller MUST be connected to the metal CASE/CHASSIS of the LCD. The whole setup should be very well grounded.
  * Isolate the USB/Serial cable away from other cables eg. VGA, power or data cables.
* Isolate the USB/Serial cable away from other cables eg. VGA, power or data cables.
  * Try to locate the controller board away from power supplies, printers, inverters or any other electronic components in your in your unit.
* Try to locate the controller board away from power supplies, printers, inverters or any other electronic components in your in your unit.
  * Standard configuration functions with non-metallic, non-conductive single construction glass which caters for up to 20mm inclusive of glass and air gap.
* Standard configuration functions with non-metallic, non-conductive single construction glass which caters for up to 20mm inclusive of glass and air gap.
  * please note that 1mm of air is equal to 3mm of glass
* please note that 1mm of air is equal to 3mm of glass
  * It is important to allow for circulation of air in front of the LCD.
* It is important to allow for circulation of air in front of the LCD.


Original-Abstandshalter war ~11x11mm (vermutlich Acryl)